RDIG-STA (Remote Digital Station)
Issue 1 May 2002
8-1347555-233-143
Notes:
a. Error type - 1; with Aux Data of 40987Could be caused by a noisy port
or link. This is an off-board problem detected by the port circuit. Check for
defective wiring, a defective voice terminal, or move the voice terminal
closer to the switch (in terms of feet of wire from the jack to the switch). If
the problem persists, replace the circuit pack. Once the problem has been
resolved, the alarm disappears after a predetermined amount of time.
Error Type - 1; with Aux Data of 1 to 20Occurs when at least 15
off-board problems have been detected with the link to the terminal. When
an error with the link is detected, an on-board counter is incremented.
The user could experience a noisy port or link. This is an off-board
problem detected by the port circuit. Check for defective wiring, a defective
voice terminal, or move the voice terminal closer to the switch (in terms of
feet of wire from the jack to the switch). If the problem persists, replace the
circuit pack. Once the problem has been resolved, the alarm disappears
after a predetermined amount of time.
b. Error Type - 18Logged when the port in question is busied out by
maintenance personnel. Make sure the port is released from busyout by
the release port UUCSSpp | PCSSpp command.
c. Error Type - 257Indicates problems transmitting to the voice terminal,
which can be caused by defective wiring. Defective wiring can cause
varying degrees of problems on different types of sets.
d. Error Type - 513The result of an ID Request failure to respond to the
digital endpoint audit.
e. Error Type - 767An in-line event produces this error type when a
favorable response is received from running the Digital Line Electronic
Power Feed test (#11). No craft action is necessary. This alarm will be
resolved with the passing of time.
f. Error Type - 769; with Aux Data 40963The result of an unfavorable
response to the Electronic Power Feed/ Positive Temperature Coefficient
test (#11).
Error Type - 769; with Aux Data 40988Indicates that the EPF/PTC
circuit has been turned off due to an overcurrent condition.
Once the problem has been resolved, it may take up to one hour for the
alarm to clear due to the leaky bucket strategy. If the problem cannot be
resolved by one of the steps above, then replace the circuit pack.
g. Error Type - 1025A problem with the voice terminal EEPROM. When
the voice terminal is repaired the alarm will be resolved with the passing of
time.