RDIG-STA (Remote Digital Station)
Issue 1 May 2002
8-1353555-233-143
Table 8-548. Test #17 Station (Digital) Audits Test
Error
Code
Tes t
Result Description / Recommendation
1 ABORT Switchhook audit timed out.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
2 ABORT ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
3 ABORT The EPF has detected an overcurrent condition.
1. Use test UUCSSpp long. If Test #11 passes, then the EPF condition was
cleared. Rerun the short test sequence. If Test #11 does not pass, follow
the repair procedures described for Test #11.
2. Look for Error Type 769 logged against RDIG-STA, and follow the
procedures in the associated footnote. If any additional problems are
found, rerun the test.
4 ABORT Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals up to 5 times.
5 ABORT Ringer update aborted due to station being in ready-for-service or
out-of-service state.
6 ABORT This port may have been busied out by a system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error is present, release the port using the release station command.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t for the port).
2. If either list config or display port indicate that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.