Maintenance-Object Repair Procedures
555-233-143
8-1354 Issue 1 May 2002
2000 ABORT Response to the test was not received in the allowable time period.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Station audits passed. This Digital Port circuit pack is functioning properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Table 8-548. Test #17 Station (Digital) Audits Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page