Maintenance-Object Repair Procedures
555-233-143
8-1464 Issue 1 May 2002
109 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 9.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 1793, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 1793, replace the SNI in
slot 9. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
112 FAIL The SNI circuit pack cannot communicate with the active SNC.
1. Check the error log for other SNI circuit packs in the same carrier with a
257 SNI-BD error. Use display errors with category PNC to view SNI-BD
errors. If other SNI circuit packs in the same switch node carrier have error
257, then replace the active SNC in this switch node carrier. Replacing an
SNC may be service interrupting. See ‘‘SNC-BD (Switch Node Clock
Circuit Pack)’’ on page 8-1384 for the procedure for replacing an SNC. If
other SNI circuit packs in the same carrier do not have SNI-BD error type
257 logged, proceed to step 2.
2. Replace this SNI. Replacing an SNI may be service interrupting. See
‘‘SNI-BD (SNI Circuit Pack)’’ on page 8-1429 for the procedure for
replacing an SNI.
3. Replace the active SNC in the same switch node carrier. Replacing an
SNC may be service interrupting. See ‘‘SNC-BD (Switch Node Clock
Circuit Pack)’’ on page 8-1384 for the procedure for replacing an SNC.
113 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 13.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 2049, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 2049, replace the SNI in
slot 13. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
Table 8-579. TEST #759 Configuration Audit — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page