SNI-BD (SNI Circuit Pack)
Issue 1 May 2002
8-1467555-233-143
120 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 20.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 3841, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 3841, replace the SNI in
slot 20. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
133 FAIL No neighbor link is administered, but the SNI has an EI neighbor.
1. Administer the SNI on a fiber link to the EI neighbor it is connected to via
the add fiber-link next command. Or remove both fiber endpoints (i.e.,
this SNI and its EI neighbor) and remove the fiber endpoints from circuit
pack administration via change circuit-pack.
134 FAIL No neighbor link is administered, but the SNI has an SNI neighbor.
1. Administer the SNI on a fiber link to the SNI neighbor it is connected to via
the add fiber-link next command. Or remove both fiber endpoints (i.e.,
this SNI and its SNI neighbor) and remove the fiber endpoints from circuit
pack administration via change circuit-pack.
135 FAIL The SNI circuit pack cannot communicate with its neighbor. The SNI has an
administered neighbor, but cannot communicate with its neighbor.
1. Check if the administered neighbor is inserted. If not, insert the neighbor
circuit pack.
2. Perform the Fiber Fault Isolation Procedure described in Chapter 5.
136 FAIL The SNI’s administered neighbor does not match the physical neighbor
connected. The type of neighbor administered is an SNI and the type of
neighbor physically connected is an EI. Enter list fiber-link, and verify that the
fiber-optic and metallic cable connections are installed as administered.
137 FAIL The SNI’s administered neighbor does not match the physical neighbor
connected. The type of neighbor administered is an EI and the type of
neighbor physically connected is an SNI. Enter list fiber-link, and verify that
the fiber-optic cable and metallic cable connections are installed as
administered.
Table 8-579. TEST #759 Configuration Audit — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page