Maintenance-Object Repair Procedures
555-233-143
8-1466 Issue 1 May 2002
117 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 17.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 3073, replace the SNI
being tested. Replacing an SNI may be service interrupting. See‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 3073, replace the SNI in
slot 17. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
118 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 18.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 3329, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 3329, replace the SNI in
slot 18. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
119 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 19.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 3585, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 3585, replace the SNI in
slot 19. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
Table 8-579. TEST #759 Configuration Audit — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page