Maintenance-Object Repair Procedures
555-233-143
8-1472 Issue 1 May 2002
Packet Neighbor Link Test (#767)
This test is nondestructive.
This test checks the packet path of the neighbor circuit pack and the peer circuit
packs. A packet is sent from the SNI being tested to the peer SNIs and to the
neighbor EI or SNI. If the other EI or SNI sends the same data back in the packet,
this test passes. Otherwise, this test fails.
Table 8-581. TEST #767 Packet Neighbor Link Test
Error
Code
Tes t
Result Description / Recommendation
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2302 ABORT Software received incorrect message data from the SNI circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2303 ABORT The SNI circuit pack responded that the software test requested is invalid.
1. Retry the command at 1-minute intervals up to 3 times.
2304 ABORT SNI firmware is not able to run the test. For this particular test, the SNI circuit
pack must be able to communicate with its neighbor.
1. Verify that the SNI can communicate with its neighbor by checking the
yellow LED of the SNI to make sure the SNI is in frame or by running the
test board command for the SNI and checking test 989 for fiber
out-of-frame. If the results of Test 989 indicate that the fiber is
out-of-frame, follow the recommendation associated with the test failure. If
a DS1 converter complex exists on the fiber link, enter display errors and
follow the associated repair procedures for any DS1C-BD and DS1-FAC
entries.
2. Retry the command at 1-minute intervals up to 3 times.
Continued on next page