SYS-PRNT (System Printer)
Issue 1 May 2002
8-1541555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. The System Printer Link has been busied out.
b. A failure was encountered while attempting to set up the System Printer
Link. This attempt could have been initiated by either Report Scheduler
software or by link maintenance during automatic link retry or as a result of
a Link Retry test (#215) request. The Aux Data field indicates the
following:
See the preceding section ‘‘Procedures for Restoring the System Printer
Link’’ on page 8-1540 for recommended maintenance strategy.
c. The SYS-PRNT was interrupted for one of the following reasons:
The cable to the SYS-PRNT output device is disconnected
The SYS-PRNT output device is powered off
The data extension to which the SYS-PRNT output device connects
has been busied out
Internal software error
Check the connectivity of the wires and cables among the wall jacket, data
module, and SYS-PRNT output device. Follow the instructions provided in
‘‘Procedures for Restoring the System Printer Link’’ on page 8-1540.
Table 8-597. SYS-PRNT Maintenance Error Log Entries
Error
Type Aux Data Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Val ue
0 0 Any Any Any test sp-link
18 (a) 0 busyout sp-link WARNING OFF release sp-link
257(b) 1, 3 4, 5, 6 Link Retry test (#215) MINOR
1
WARNING
1. Minor alarms may be downgraded to Warning alarms based on the value used in the set options command.
OFF test sp-link l
513 (c) 0 None MINOR OFF test sp-link
1 No C-LAN port available. See ‘‘CLAN-BD (Control LAN Circuit Pack)’’ on
page 8-411 for explanation.
3, 4 Time-out during setup attempt. Most likely due to problem with physical
link or printer status.
5 Internal system error. Most likely temporary/sporadic failure.
2, 6 The data module the printer is trying to use is busy with another call. Use
the Status data module command to determine when the port is
available for testing.

Table of Contents