Maintenance-Object Repair Procedures
555-233-143
8-1542 Issue 1 May 2002
System-Technician-Demanded Tests:
Descriptions And Error Codes
When inspecting errors in the system and deciding which ones to address, always
investigate errors in the order they are presented in the table below. For example,
by clearing error codes associated with the Link Tear Down test (#213), you may
also clear errors generated from other tests in the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
The Link Tear Down test disconnects the existing link between S8700
Multi-Connect and the external SYS-PRNT output device. If the link has been
disconnected already, this test just returns PASS. Every resource allocated for a
System Printer Link is released after this test.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Nondestructive
Link Tear Down test (#213) X D
Link Retry test (#215) X X ND
Table 8-598. TEST #213 Link Tear Down Test
Error
Code
Tes t
Result Description / Recommendation
40, 50 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to two times.
1010 ABORT The System Printer Link has been busied out.
1. Enter the release sp-link command to release the System Printer Link
from the busyout state.
2. Reissue the test sp-link long command to execute the test.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to five times.
FAIL Internal system error.
1. Retry the command at 1-minute intervals up to two times.
PASS The System Printer Link is torn down, or a short test sequence was executed
and the link was not torn down.