SYS-PRNT (System Printer)
Issue 1 May 2002
8-1543555-233-143
Link Retry Test (#215)
This test sends a message to the System Printer management software process
instructing it to make a data call to the extension connected to the printer. If the
System Printer link is already up, this test passes without making any data call.
Table 8-599. TEST #215 Link Retry Test
Error
Code
Tes t
Result Description / Recommendation
10, 20 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to two times.
30 ABORT Internal system error.
1. See ‘‘Procedures for Restoring the System Printer Link’’ on page 8-1540
for recommended maintenance strategy.
1010 ABORT The System Printer Link has been busied out.
1. Enter the release sp-link command to release the System Printer Link
from the busyout state.
2. Reissue the test sp-link long command to execute the test.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to five times.
FAIL The System Printer Link CANNOT be established.
1. See ‘‘Procedures for Restoring the System Printer Link’’ on page 8-1540
for recommended maintenance strategy.
PASS The System Printer Link is up.
Continued on next page