Maintenance-Object Repair Procedures
555-233-143
8-1640 Issue 1 May 2002
769(l) 57481 EPF M and E Lead (#74) MAJOR
MINOR
WARNING
2
ON test port UUCSSpp sh r 3
1025(m) Any None MAJOR
MINOR
WARNING
2
OFF
1281(l) Any EPF M and E Lead (#74) MAJOR
MINOR
WARNING
2
ON test port UUCSSpp sh r 3
1537 Looparound and
Conference (#33)
MAJOR
MINOR
WARNING
2
ON test port UUCSSpp l r 3
1793 Tie Trunk Seizure (#73)
(Dial Test #747 for
TN439)
MAJOR
MINOR
WARNING
2
OFF test port UUCSSpp sh r 2
2049 NPE Crosstalk (#6) MAJOR
MINOR
WARNING
2
ON test port UUCSSpp l r 3
2305(n) 57424
50944
None (l)
2561(o) 0 None WARNING OFF
2562(p) 16665
2817(o) 0 None MINOR OFF
2817(q) 52992
3073(o) 0 None
3840(r) 8000 Transmission tests
(ATMS)(#844-848)
OFF test analog-testcall
3841(r) Transmission tests
(ATMS)(#844-848)
MINOR OFF test analog-testcall
UUCSSpp r 2
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command. If the MINOR alarm is not downgraded by the set options values, then the MINOR alarm will be
upgraded to a MAJOR alarm if 75% of the trunks in this trunk group are alarmed. These errors, if applicable,
always log a MINOR alarm for TN439 and TN497.
Table 8-637. TIE Trunk Error Log Entries Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page