TTR-LEV (TTR Level)
Issue 1 May 2002
8-1701555-233-143
Error Log Entries and Test to Clear Values
!
WARNING:
The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12
(France).
Notes:
a. Error code 1 does not indicate a current error condition. It indicates that
the number of DTMR ports in service was below the administered
threshold, but is now equal to or greater than the threshold. These errors
are typically generated during boot time or other transitional states when
the ports are being brought into service.
b. The total number of DTMR ports currently in service is below the
administered threshold. To clear the alarm, see ‘‘Repair Procedure for
TTR-LEV’’ on page 8-1700.
c. Error code 3 does not indicate a current error condition. It indicates that
the number of GPTD ports in service was below the administered
threshold, but is now equal to or greater than the threshold. These errors
are typically generated during boot time or other transitional states when
the ports are being brought into service.
d. The total number of GPTD ports currently in service is below the
administered threshold. To clear the alarm, see ‘‘Repair Procedure for
TTR-LEV’’ on page 8-1700.
Table 8-659. TTR Level Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
1 (a) 1 None
2 (b) 2 WARNING
(See WARNING
message below)
OFF
3 (c) 3 None
4 (d) 4 WARNING OFF
5 (e) 5 None
6 (f) 6 WARNING OFF
7 (g) 7 MAJOR OFF
8 (h) 8 MINOR OFF
9 (i) 9 MINOR OFF