EasyManua.ls Logo

Avaya S8700 - Page 2445

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1723555-233-143
2306 Any Yellow Alarm Inquiry
test (#141)
WARNING
3
MINOR
OFF test board UUCSS
2561 Any Major Alarm Inquiry test
(#142)
WARNING
3
MINOR
OFF test board UUCSS
2817 Minor Alarm Inquiry test
(#143)
WARNING
3
MINOR
OFF test board UUCSS
3073 to
3160 (v)
Any Slip Alarm Inquiry test
(#144)
WARNING
3
MINOR
OFF test board UUCSS r 6
3330(w) 46083 WARNING
3
MINOR
ON
3585 to
3601 (x)
Any Misframe Alarm Inquiry
test (#145)
WARNING
3
MINOR
OFF test board UUCSS r 6
3840(y) Any None
3841(z) 4358
3842(aa) 46097
3843(ab) 46081
3900(ac) Any CPE Loop-Back Jack
test (#1212)
3901(ad) Any Far CSU Loopback test
(#1213)
3902(ae) Any One-Way Span test
(#1214)
3999(af) Any None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit pack,
then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a period of 15
minutes. Warning alarms are also raised against any ports administered on the circuit pack.
3. Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options
command.
4. Major alarms on this MO may be downgraded to minor or warning alarms based on values set in the set options
command.
Table 8-667. DS1 Interface Circuit Pack Maintenance Error Log Entries Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page

Table of Contents

Other manuals for Avaya S8700

Related product manuals