VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 May 2002
8-1821555-233-143
j. Error Type 1798 — Unable to write translation RAM.
1. Attempt to clear alarm (reset board UUCSS).
2. If alarm recurs within 15 minutes, replace the circuit pack.
k. Error Type 2049 — Packet Interface test (#598) failed.
1. Attempt to clear the alarm (test board UUCSS l r 3).
2. If alarm does not clear, reset the circuit pack (reset board UUCSS).
3. If circuit pack resets, execute Packet Interface test (#598) several
times.
4. If Packet Interface test (#598) continues to fail, replace the circuit
pack.
l. Error Type 2305-230 — Error in received frame from packet bus.
Most likely cause — packet bus problem.
Other cause — circuit pack fault.
Invalid LAPD frame errors occur when the frame
■ contains a bad Cyclic Redundancy Check (CRC)
■ is greater than the maximum length
■ violates the link-level protocol
1. Retry the command (test board UUCSS) and see if the condition
clears.
2. If condition persists, execute PPE/LANBIC Receive Parity Error
Counter test (#597) and determine whether the condition clears.
3. If condition persists, execute Packet Interface test (#598) to verify
circuit pack integrity.
4. If Packet Interface test (#598) fails, consult repair procedure for the
packet bus.
Error Type: Description
2305 Received invalid LAPD frame.
2306 Detected parity error on received frame.