VC-DSPPT
Issue 1 May 2002
8-1855555-233-143
Table 8-710. Test #1105 VC-DSP Port DSP Loop-Back Test
Error
Code
Te s t
Result Description / Recommendation
1000 ABORT System resources required to run this test are not available, or the port is busy
with a valid call.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test, the traffic load on the
system is very high, or time slots are out-of-service due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a Tone Detector for the test, the system is
oversized for the number of Tone Detectors present, or some Tone Detectors
are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004 ABORT The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port and determine whether the
port is available for testing
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test request was not received from the VC-BD circuit pack
within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the other ports are
idle by using the busyout port UUCSSpp and reset port UUCSSpp
commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
0, 1 FAIL The VC-DSPPT DSP Loopback test failed.
1. Replace the circuit pack.
PASS The VC DSPPT DSP Loopback test passed
Continued on next page