WAE-PORT (Wideband Access Endpoint Port)
Issue 1 May 2002
8-1869555-233-143
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Use status health to determine whether the system is
experiencing heavy traffic.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
too big for the number of Tone Detectors present, or some Tone Detectors may
be out of service. List measurement tone-receiver displays information
about the systems tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004 ABORT The port has been seized by a user for a valid call. Use status
access-endpoint extension to determine when the port is available for testing.
The port is available when it is in the in-service/idle state.
1. Retry the command at 1-minute intervals up to 5 times.
1020 ABORT The test did not run because of a previously existing error on the specific port
or a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The NPE of the tested port was found to be transmitting in error. This causes
noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
1. Investigate user-reported troubles on this port using other port tests and by
examining the terminal adapter or external wiring.
Table 8-717. Test #6 NPE Crosstalk Test Continued
Error
Code
Test
Result Description / Recommendation