Maintenance-Object Repair Procedures
555-233-143
8-1868 Issue 1 May 2002
Technician-Demand Tests: Descriptions and Error
Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
NPE Crosstalk test (#6), you may also clear errors generated from other tests in
the testing sequence.
NPE Crosstalk Test (#6)
The NPE Crosstalk test verifies that this ports NPE channel talks on the selected
time slot, and does not cross over to time slots reserved for other connections. If
the NPE is not working correctly, 1-way and noisy connections may be observed.
This test is usually part of a ports long test sequence and takes 20 to 30 seconds
to complete
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6) X ND
Conference Circuit test (#7) X ND
Port Audit and Update test (#36) X X ND
Table 8-717. Test #6 NPE Crosstalk Test
Error
Code
Test
Result Description / Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
in use on a valid call. Use the status access-endpoint extension or command
to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1001 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.