EasyManua.ls Logo

Avaya S8700 - Page 378

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Commands
555-233-143
7-122 Issue 1 May 2002
1922 IP RRJ-TTI or RO
inactive
Registration for an IP set with TTI
service rejected. Possible causes:
TTI is not enabled on the
System Parameters Customer
Options screen.
Remote Office is not enabled
on the System Parameters
Feature Options screen.
0 IP address
1923 IP RRJ-No E164
number
Registration rejected; no valid
E.164 phone number available.
The extension is not administered.
UID IP address
1924 IP RRJ-No GRQ msg
rcvd
Registration rejected; did not
receive a Gatekeeper Request
message
UID IP address
1925 IP RRJ-RQ: new LM
fail
Registration rejected; failure
creating a new Login Manager.
Possible cause:
No available heap memory to
create LoginMgr
Cannot start LoginMgr timer
Clock not set
UID IP address
1926 IP
RRJ-Authentication
fail
Registration rejected:
authentication failure. The
password that the user entered
and the administered password on
the station screen do not match.
UID IP address
1927 IP RRJ-Invld station
type
Registration rejected:
invalid set type
no Remote Office or IP
Softphone administration on
the station screen
UID Type
Table 7-16. Denied IP events Continued
Event
Type Event Description Explanation
Event
Data 1
Event
Data 2
Continued on next page