display events
Issue 1 May 2002
7-121555-233-143
1913 IP RRJ-Invalid
ProdID/Ver
Registration rejected because
invalid Product ID / Version.
Registering Application’s product
ID is not administered or no
Product ID in RRQ message.
T/S:
Product ID
of the
registering
application
Major
version
number
1914 IP RRJ-ProdID
search fail
Registration rejected because the
search for registering application’s
Product ID failed.
T/S:
Product ID
of the
registering
application
Major
version
number
1915 IP RRJ-Invalid
endpt/Ver
Registration rejected because the
endpoint version is not compatible
with the gatekeeper version.
IP address Major
version
number in
2nd byte;
minor
version
number in
low byte
1916 IP RRJ-No H323
NonStdData
Registration rejected;
non-standard data are missing in
the RRQ from authenticating
application.
0 IP address
1917 IP RRJ-Invld H323
ObjID
Registration rejected; Object ID in
the RRQ is invalid.
Object ID IP address
1918 IP RRJ-Invld H225
NSData
Registration rejected; cannot
decode H225 non-standard data
(NSD) message.
0 IP address
1919 IP RRJ-Bad H225
NSDchoice
Registration rejected; unexpected
NSD message received from
registering application.
NSD choice IP address
1920 IP RRJ-TTI: new LM
fail
Registration rejected; failure in
creating new Login Manager.
Possible causes are:
■ No available heap memory to
create LoginMgr
■ Cannot start LoginMgr timer
■ Clock not set
UID IP address
1921 IP RRJ-IP-TTI port
fail
Registration rejected; failure when
inserting IP TTI port.
UID IP address
Table 7-16. Denied IP events — Continued
Event
Type Event Description Explanation
Event
Data 1
Event
Data 2
Continued on next page