Maintenance Commands
555-233-143
7-136 Issue 1 May 2002
Field Descriptions
Cause
This gives the reason for the system reset, as follows:
Agent Request: The restart was requested through the Agent/GEMINI
debugger interface (not available to craft login).
Craft Request: The reset was initiated using reset system.
Initialized: This represents a power-up, and is always the first entry in the
log unless more than 15 restarts have occurred since the last power up.
Interchange: A spontaneous interchange was executed by the system.
Scheduled Interchange: A scheduled interchange was executed by the
system.
Action
The level of recovery performed by the system.
1 Reset system 1 (Warm)
2 Reset system 2 (Cold-2)
4 Reset system 4 (Reload)
Escalated
Whether the restart was escalated to a higher level than originally
attempted. The systems software escalation strategy can perform a higher
level restart than the one initiated if problems prevent or conditions interfere
with normal execution.
Time
The month, day and time of the restart.