display initcauses
Issue 1 May 2002
7-137555-233-143
Output (for S8700 IP Connect)
Field Descriptions
Cause
This gives the reason for the system reset, as follows:
Internal Request: A fault has triggered the system to automatically reset.
Software Request: A reset has been manually requested by a user.
Initialized: This represents a power-up, and is always the first entry in the
log unless more than 15 restarts have occurred since the last power up.
Action
The level of recovery performed by the system.
1 Reset system 1 (Warm)
2 Reset system 2 (Cold-2)
4 Reset system 4 (Reload)
Escalated
Whether the restart was escalated to a higher level than originally
attempted. The system’s software escalation strategy can perform a higher
level restart than the one initiated if problems prevent or conditions interfere
with normal execution.
Time
The month, day and time of the restart.
display initcauses
INITIALIZATION CAUSES
Cause Action Escalated Time
Internal Request 1 no 03/09 11:58
Software Request 4 yes 03/09 18:33
Internal Request 1 no 03/09 18:34
Internal Request 1 no 03/09 18:34
Internal Request 1 no 03/09 18:34
Internal Request 1 no 03/09 21:39
Initialized 4 no 03/11 15:17
Internal Request 1 no 03/11 15:18
Internal Request 1 no 03/11 15:18
Internal Request 1 no 03/11 15:18
Initialized 4 no 03/11 15:28
Internal Request 1 no 03/11 15:29
Internal Request 1 no 03/11 15:29
Internal Request 1 no 03/11 15:29
Internal Request 1 no 03/19 12:21
Software Request 4 no 03/19 12:22
Command successfully completed