list measurements ds1
Issue 1 May 2002
7-191555-233-143
Field Descriptions
The following field descriptions pertain to the summary reports accessed by list
measurements ds1
and list measurements ds1-facility summary.
Counted Since:
The start time and date when the associated measurement counters
were cleared, or when the DS1C circuit pack or facility was administered.
Number of
Seconds Elapsed
Into Current
15-min
Interval:
The number of seconds from the beginning of the current 15-minute
interval. This field has a value from 0 to 900.
Total of Valid
15-min
Intervals in
Past 24-hr
Period:
The total number of 15-minute intervals in the past 24-hour period that
contain valid data. This field has a value from 0 to 96.
Category
The following four fields report data form the error counters.
Errored Seconds
The value of the errored seconds counter for the specified 15-minute
interval. This field has a value from 0 to 900 or N/A if the data for the
15-minute interval is invalid.
Bursty Err Secs
The value of the bursty errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if the data
for the 15-minute interval is invalid.
Severely Err
Secs
The value of the severely errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if the data
for the 15-minute interval is invalid.
Failed Seconds
The value of the failed seconds counter for the specified 15-minute
interval. This field has a value from 0 to 900 or N/A if the data for the
15-minute interval is invalid.
Worst 15-Min
Interval
The date (Date), end time (Time), and error count (Count; from 0 to 900
in increments of four) of the 15-minute interval in the previous 24-hour
period that contains the maximum value for each of the four error
categories (errored seconds, bursty errored seconds, severely errored
seconds, and failed seconds).
Total of 24-Hour
Counts
The sum of every valid 15-minute count for the previous 24-hour period
for each of the four error categories. This field has a value from 0 to
65535.
Current
15-Minute
Interval
The error count for the current (incomplete) 15-minute interval for each of
the four error categories. This field has a value from 0 to 899 or N/A if the
data for the current 15-minute interval is invalid.