Maintenance Commands
555-233-143
7-192 Issue 1 May 2002
The following field descriptions pertain to the detailed reports accessed by the list
measurements ds1-log
and list measurements ds1-facility log commands.
Counted
Since:
The start time and date when the associated measurement counters were cleared
or the DS1C circuit pack was administered.
Date
The date of the 15-minute interval.
Time
The time of the 15-minute interval.
Errored
seconds
The value of the errored seconds counter for the specified 15-minute interval.
This field has a value from 0 to 900 or N/A if the data for the 15-minute interval is
invalid.
Bursty err
secs
The value of the bursty errored seconds counter for the specified 15-minute
interval. This field has a value from 0 to 900 or N/A if the data for the 15-minute
interval is invalid.
Valid
interval
This field indicates whether the data for the specified 15-minute interval is valid.
Data is considered valid when a count for that 15-minute interval. If the field has a
value of y, the data for the four error categories is valid; otherwise, the data is
invalid. Data is considered valid when a count for that 15-minute interval is
retrieved and none of the following invalid conditions occur. Data is invalid if a
system warm start or a system cold start occurred during the interval, if the DS1C
circuit pack was not inserted during the interval, if the system time was changed
during the interval, or if the system was too busy to respond to a poll request for
the interval.