status bri-port
Issue 1 May 2002
7-301555-233-143
ASAI
BRI
0-126 Hyperactive ignore ignore Link has sent too many messages
per unit time. Signaling has been
suspended. After 60 seconds, the
system attempts to put the link into
service. If a link remains in this state
while there is no activity at the BRI
endpoint, take the following steps:
1. Make sure SPID administration
on the switch and endpoints are
consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
L3-Established. If it is
not, go to Step 2.
2. Try replacing the endpoint.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
L3-Established. If it is
not, follow normal escalation
procedures.
ASAI 0-126 L3-Restarting ext# The switch has sent a Restart
message to the adjunct but has not
yet received a Restart
Acknowledgment message from the
adjunct.
ASAI 0-126 L3-Restarted ext# After receiving a Restart
Acknowledgment message, the
switch has sent a Heartbeat
message to the adjunct and is
waiting for a response.
ASAI 0-126 L3-Established ext# This is the normal state for ASAI
adjunct.
Table 7-45. Interpreting BRI-Port Status Reports Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page