test ds1-loop
Issue 1 May 2002
7-427555-233-143
If the specified board is not inserted in the system, the following message will be
displayed:
Board not inserted
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
login id:command has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then
resubmit
If every available maintenance resource is currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
If the test ds1-loop command is executed and the G3 Version field on the
System Parameters Customer Options form is not V3 or later, then the following
message will be displayed:
G3 Version must be V3 or later
If the test ds1-loop command is executed on a circuit pack other than TN464F or
TN767E or later DS1 board, then the following message will be displayed:
Command valid for TN464F or TN767E or
later release DS1 circuit packs
If the [inject-single-bit-error] parameter is selected, but no CPE loopback jack,
far-end CSU, or one-way span test is active on the DS1 circuit pack, then the
following message will be displayed:
Parameter valid only if a loopback/span test is active on
the DS1