Maintenance-Object Repair Procedures
555-233-143
8-20 Issue 1 May 2002
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port was put in use during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the port is active, wait until it is idle before
testing.
1020 ABORT Test disabled by background testing. Use the status station command to
determine when the voice port is available for testing.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1, 2 FAIL The NPE of the tested port is transmitting in error. This causes noisy and
unreliable connections. Failure code 1 indicates that the Crosstalk test failed
on the primary channel. Failure code 2 indicates that the Crosstalk test failed
on the secondary channel.
1. Replace the circuit pack.
PASS The port is using its allocated time slots correctly.
1. To be sure that this is not an intermittent problem, repeat this test up to 10
times to make sure it continues to pass.
2. If complaints still exist, examine the connections.
Table 8-7. Test #9 NPE Crosstalk Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page