ADX8D-PT (AUDIX Digital Port)
Issue 1 May 2002
8-21555-233-143
Voice and Control Channel Local Loop Test (#13)
This test checks the information and control channels between a server and the
EMBEDDED AUDIX port circuit. First, the primary information (voice) channel
loop back test is run.
While the primary information channel is still looped around, the Control Channel
Looparound test is performed. The Looparound test for the secondary
information (data) channel is then performed. This is the same test as the primary
information channel’s loop-around test.
Next, a Conference test is implemented for the primary information channel. This
is the same test as Conference test (#6).
Only one value (Pass, Fail, or Abort) is generated as a result of the four tests run.
If any tests fail or abort, the sequence is stopped.
Table 8-8. Test #13 Voice and Control Channel Local Loop Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times. Then try (b).
1000 ABORT System resources required to run this test are not available. The port may be
active.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the service state indicates that the port is active,
wait until it is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1001 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or may have time slots that are out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
Continued on next page