1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004 ABORT The port was put in use during the test.
1. Use the display port UUCSSpp to determine the voice port extension of
the port. Use the status station command to determine the service state
of the port. If the service state indicates that the port is active, wait until it is
idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 FAIL Conference test failed on the primary channel. Some users may notice a
disruption in service. In extreme cases, the conferencing feature may not work
at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may range
from no noticeable effect to loss of use of this port.
15 FAIL The control channel between the processor and the EMBEDDED AUDIX circuit
pack is not transmitting properly. User impact may range from no noticeable
effect to loss of use of this port.
16 FAIL The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
None FAIL The test failed for reasons external to the EMBEDDED AUDIX circuit pack.
1. Run circuit pack tests to check the IPSI Tone Generator circuit or the Tone
Generator circuit pack and the IPSI Tone Detector circuit or Tone Detector
circuit pack by using the test board UUCSS s command.
2. Resolve any problems that are detected on the Tone Generator circuit or
Tone Detector circuit.
3. If both circuit packs are functioning properly and the test still fails, replace
the EMBEDDED AUDIX circuit pack (see caution at the beginning of this
section).
Table 8-8. Test #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page