ADX16D-P (16-Port AUDIX Digital Port)
Issue 1 May 2002
8-27555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy port or link, due to an off-board problem
that is detected by the port circuit. If so, replace the circuit pack (see
caution at the beginning of this section). Once the problem is resolved, the
alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the voice
port. When an error with the link is detected, an on-board counter is
incremented. Also see Note a, above.
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. Release the port with the release
port UUCSSpp command.
Table 8-9. EMBEDDED AUDIX Digital Port Error Log Entries
Error
Type
Aux
Data
Associated
Tes t
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any AnyAnytest port UUCSSpp sh r 1
1(a) 40987 None WARNING OFF
1(b) 1 to 20 None WARNING OFF
15(c) Any None
18(d) 0 busyout port
UUCSSpp
WARNING OFF release port UUCSSpp
23(e) 0 None WARNING OFF
130(f) None WARNING ON test port UUCSSpp sh
257(g) 40971 None
513(h) Any None
1537(i) 40968 None WARNING OFF
1793 Voice and
Control Local
Loop Test
(#13)
MINOR
WARNING
2
2. Minor alarms may be downgraded to Warning alarms based on the values used in the set options command.
ON test port UUCSSpp l r 3
2049 NPE Crosstalk
test (#9)
MINOR
WARNING
2
ON test port UUCSSpp l r 3
2305(j) 40967 None
3840(k) 40965 None
3840(l) 41029 None