ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 May 2002
8-35555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port UUCSSpp command.
b. The circuit pack has been logically administered but not physically
installed. The alarm will be cleared when the circuit pack is installed.
c. The circuit pack has been removed or has been insane for more than
11 minutes. To clear the error, reseat or replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only one analog circuit pack in
the system has this problem, then replace the circuit pack. If only analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, check the ringing generator.
e. AUDIX is not available to the switch. Check the AUDIX system, referring to
EMBEDDED AUDIX System Maintenance, 585-300-110.
f. The TDM bus is out of service. See ‘‘TDM-BUS (TDM Bus)’’ on page
8-1588.
Table 8-12. EMBEDDED AUDIX Analog Line/Control Link Error Log Entries
Error
Type
Aux
Data Associated Test
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40977 None
18 0 busyout station
extension
WARNING ON release station extension
23 (b) 0 None WARNING OFF
130 (c) None WARNING ON test port UUCSSpp sh
257 (d) 40973 None
513 (e) Any None
1025 (f) Looparound test
(#161)
MINOR
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON test port UUCSSpp l r 2
1281 Conference test
(#7)
MINOR
WARNING
2
ON test port UUCSSpp l r 2
1537 NPE Crosstalk
test (#6)
MINOR
WARNING
2
ON test port UUCSSpp l r 2