ANL-16-L (16-Port Analog Line)
Issue 1 May 2002
8-47555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors and can only be resolved over time.
Aux Data 40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5
th
incoming call causes an inline error from the board.
Aux Data 40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure in the
terminal equipment or the type of terminal has a low ringer impedance.
Table 8-19. 16-Port Analog Line Error Log Entries
Error
Type
Aux
Data
Associated
Te s t
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and
Updates test
(#36)
18 0 busyout
station
extension
WARNING ON release station extension
130(c) None WARNING ON test port UUCSSpp sh
257(d) 40973 none
513(e) Station
Present test
(#48)
WARNING OFF test port UUCSSpp sh r 2
769 Battery Feed
test (#35)
MINOR
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON test port UUCSSpp sh r 2
1025 Looparound
test (#161)
MINOR
WARNING
2
ON test port UUCSSpp l r 2
1281 Conference
test (#7)
MINOR
WARNING
2
ON test port UUCSSpp l r 2
1537 NPE
Crosstalk test
(#6)
MINOR
WARNING
2
ON test port UUCSSpp l r 2