Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors and can only be resolved over time.
Aux Data 40960 indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5
th
incoming call will cause an inline error from the
board.
Table 8-26. 24-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0Any Any Anytest port UUCSSpp sh r 1
1(a) 40960
40975
40977
none
15(b) Any Audits and Updates
test (#36)
18 0 busyout station
extension
WARNING ON release station extension
130(c) None WARNING ON test port UUCSSpp sh
257(d) 40973 none
513(e) Station Present test
(#48)
WARNING OFF test port UUCSSpp sh r 2
769 Battery Feed test
(#35)
MINOR
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON test port UUCSSpp sh r 2
1025 Looparound test
(#161)
MINOR
WARNING
2
ON test port UUCSSpp l r 2
1281 Conference test
(#7)
MINOR
WARNING
2
ON test port UUCSSpp l r 2
1537 NPE Crosstalk test
(#6)
MINOR
WARNING
2
ON test port UUCSSpp l r 2
Continued on next page