Maintenance-Object Repair Procedures
555-233-143
8-82 Issue 1 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. These are in-line errors that can only be resolved over time.
Aux Data 40960 Indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5
th
incoming call will cause an inline error from the
board.
Aux Data 40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure in the
terminal equipment or the type of terminal has a low ringer impedance.
Table 8-33. 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40960
40977
40975
None
15 (b) Any Audits and Updates
test (#36)
18 0 busyout station
extension
WARNING OFF release station extension
130 (c) None WARNING ON test port UUCSSpp sh
257 (d) Station Present test
(#48)
WARNING OFF test port UUCSSpp sh r 3
513 Battery Feed test
(#35)
MINOR
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON test port UUCSSpp sh r 2
769 (e) Loop Around and
Conference test
(#47)
test port UUCSSpp l r 3
1025 NPE Crosstalk test
(#6)
MINOR
WARNING
2
ON test port UUCSSpp l r 3
1281 (f)