Maintenance-Object Repair Procedures
555-233-143
8-100 Issue 1 May 2002
FAIL The terminal equipment is not connected to the circuit pack or the ringing
generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If present,
see ‘‘RING-GEN’’ (analog ring generator) maintenance.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the set may be defective. Check the set, and replace it,
if necessary.
5. Some terminal equipment (such as a modem) could fail even when it is
connected properly. If this is the case, disable the test using the change
station extension command (enter n into the Test? field). Note that this
action also disables Tests 6, 7, 161, and 35 on this port.
PASS The station is connected properly to the switch. This test may also pass if no
terminal equipment is connected and the terminal is located very far from the
switch. Investigate user-reported troubles on this port by using other port tests
or by examining the station and its wiring.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the list config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port. If
not, dispatch to verify that a valid board is inserted.
Table 8-38. Test #48 Station Present Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page