AN-LN-PT (Analog Line Port)
Issue 1 May 2002
8-109555-233-143
Battery Feed Test (or Port Diagnostic Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery power, and detecting the resulting current.
Table 8-42. Test #35 Battery Feed Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources are unavailable. The port may be busy with a valid call.
This result is also reported for the system’s Music-On-Hold port when it is
off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s extension.
2. Enter status station extension to determine the service state of the port.
3. If the port is active, wait until it is idle. Retry the command at 1-minute
intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station extension command to determine the service
state of the port.
3. If the port is active, wait until it is idle before testing. Retry the command at
1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1018 ABORT Administration has disabled the test. The default for the Test? field on the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test #48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Change the Test? field on the station form to y.
Continued on next page