Maintenance-Object Repair Procedures
555-233-143
8-110 Issue 1 May 2002
1392 ABORT This port is currently a TTI port and the test does not execute on it.
1. Verify that the port is a TTI port:
■ Enter the display port UUCSSpp command (the display shows
that the port is a TTI port).
■ Enter the list configuration command (the display shows a t
for the port).
2. If both commands indicate that the port is a TTI port, the abort is correct for
the test, and no action is necessary.
3. If either command indicates that the port is not a TTI port, escalate the
problem.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The port’s battery feed chip is unable to supply sufficient power to the terminal
equipment. This test result might be marginal, and the terminal equipment may
be operating satisfactorily.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, determine whether the customer is experiencing
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
PASS The port’s battery feed chip is able to provide sufficient power to the station
equipment to detect on-/off-hook, but may not be able to supply power for
touch-tones.
1. If touch-tones are inoperative on this station, replace the circuit pack
because this port is inoperative.
2. Investigate user-reported troubles on this port by running other port tests,
by examining station wiring, or by inspecting the station.
Table 8-42. Test #35 Battery Feed Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page