Maintenance-Object Repair Procedures
555-233-143
8-112 Issue 1 May 2002
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and
translations with information in the software.
Table 8-43. Test #36 Station Status and Translation Audits and Updates
Error
Code
Tes t
Result Description / Recommendation
ABORT Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1004 ABORT A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station extension command to determine the service
state of the port.
3. If the port is active, wait until it is idle before testing. Retry the command at
1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1006 ABORT The port is out-of-service. The busy station extension command has been
given to this port, or it has been taken out-of-service by the failure of the NPE
Crosstalk test.
1. Look for error type 18 (port busied out) for this port. If this error is present,
release the port (release station extension), and run the test again.
2. Check for error type 1537 (NPE Crosstalk test failed) for this port. If this
error is present, investigate the errors associated with the NPE Crosstalk
test (#6).
3. Make sure that the terminal is connected and in service, and then retest.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page