AN-LN-PT (Analog Line Port)
Issue 1 May 2002
8-113555-233-143
1 FAIL The switchhook audit failed. This result does not indicate a hardware problem.
The other updates were not performed because of this failure. This may occur
if the audit is performed at the same time the terminal equipment goes off-hook.
1. Use the status station extension command to determine when the port is
available.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to fail, escalate the problem.
5 FAIL The message waiting lamp update failed. This may be an internal software
error. The translation and ringer updates were not performed because of this
failure.
7 FAIL The translation update failed. There may be an internal software error. The
ringer update was not performed because of this failure.
8 FAIL The ringer update failed. There may be an internal software error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, escalate the problem.
PASS The software and the port processor have the same status. Investigate
user-reported troubles on this port by running other port tests, by examining
station wiring, or by inspecting the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This result could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the list
configuration command, and resolve any problems.
2. If the board is correctly inserted, issue the busy board UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command.
This should re-establish the link between the internal ID and the port. If
not, verify that a valid board is inserted.
Table 8-43. Test #36 Station Status and Translation Audits and Updates — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page