ANN-PT (Announcement Port)
Issue 1 May 2002
8-137555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
b. This error is logged and the port is alarmed when an alarm is raised on the
announcement circuit pack because of a faulty condition with a common
circuit pack resource. Any one of the following alarmed errors on the
announcement circuit pack causes this error to be logged against the
Announcement Port: 1793, 2049, 2305, 2561. See ‘‘AN-LN-PT (Analog
Line Port)’’ to resolve these alarms. When the corresponding circuit pack
alarm is cleared, this alarm will clear.
Table 8-52. Announcement Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 PSMA (Playback
Speech Memory Array)
test (#206)
MINOR ON test port UUCSSpp sh r 3
18 0 The port was busied out. WARNING OFF release port UUCSSpp
130(a) None WARNING ON test port UUCSSpp sh
257 CAMA (Channel
Administration Memory
Array) test (#205)
MINOR ON test port UUCSSpp l r 3
17667 In-line error
513 140AY Channel Sanity
Inquiry test (#222)
MINOR ON test port UUCSSpp sh r 3
17684 In-line error
769(b) None