Error Log Entries and Test to Clear Values
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol.
Timers associated with certain layer-3 messages have expired before a
required response was received. In the following table, the aux data
column indicates which timer has just expired. For more information, refer
to the Avaya ISDN-BRI Specification.
Table 8-56. ASAI-EPT Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm Level
ASAI-EPT
On/ Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test ASAI-ADJ
2 (a) 2-102 None
257 (b) Any BRI Layer 3
query
MAJOR
WARNING
2
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
OFF test station ext r 2
test data-module ext r 2
351 (c) 0 none WARNING OFF busyout and release
station
513 (d) 0 None
769 (e) 0 None MAJOR OFF
2561 (f) 0 None
2562-
2566 (g)
0None
2567 (h) 0 None
2568 (i) 0 None
3329 (j) Any Signaling Link
status (#626)
MAJOR
WARNING
OFF
3584-
3839 (k)
Any None
3841 (l)
4095
Any None