Maintenance-Object Repair Procedures
555-233-143
8-150 Issue 1 May 2002
j. This occurs when the point-to-point signaling link to the endpoint goes
down, except when the link goes down because either a system technician
has busied out the PKT-CTRL or the PKT-BUS, or they have failed. This
error raises an alarm against the endpoint or adjunct. Execute the test
station extension short command and note the results of the Signaling
Link Status test (#626). If this test fails, follow the repair procedure for
Test #626. The alarm is retired when the signaling link is re-established to
the endpoint or adjunct.
k. The switch software logs certain ASAI cause values. The cause value is
determined from the following formulas:
If the error type is greater than 3712, then the ASAI cause value is
equal to the error type minus 3712. The switch sent this value to the
adjunct.
If the error type is less than 3712, then the ASAI cause value is
equal to the error type minus 3584. The adjunct sent this value to
the switch.
Table 8-57 contains a description of the various ASAI cause values and
recommended system technician actions associated with the cause value.
The ISDN-BRI Specification contains further information.
l. The switch software logs certain ASAI cause values. The cause value is
determined from the following formula:
If the error type is greater than 3968, then the ASAI cause value is
equal to the error type minus 3968. The switch sent this value to the
endpoint.
If the error type is less than 3968, then the ASAI cause code is
equal to the error type minus 3840. The endpoint sent this value to
the switch.
Table 8-57. ASAI Cause Values
Code Explanation Recommendation
0 Unrecognized
ASAI Protocol
Operation.
Requested ASAI protocol is not implemented by switch or adjunct.
Aux
Data
field of error log entry contains protocol identifier for
unrecognized operation.
1. Consult switch and adjunct documentation to determine which set
of operations is supported by switch and the adjunct. Turning off
adjunct operations not implemented by the switch may resolve the
problem.
Continued on next page