Maintenance-Object Repair Procedures
555-233-143
8-156 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when the Level 1 Status inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The
Aux Data field contains one of the following values:
Refer to the repair procedures for Test #621.
b. The circuit pack is having problems transmitting data to the packet bus,
thus affecting the conveyance of signaling information over the D channel.
This error occurs when the packet bus transmit FIFO buffer overflows.
This condition probably indicates a hardware problem as well. The
ASAI-PORT alarm level is MAJOR with aux data 0. Use troubleshooting
procedures for both on-board hardware problems and potential off-board
packet-bus problems.
Table 8-59. ASAI-PT Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm Level
ASAI-PORT
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) (a) Level 1 Status
inquiry (#621)
MAJOR
2
2. Major and Minor alarms may be downgraded to warning alarms based on the value used in the set options
command.
OFF test port UUCSSpp sh r 2
513 (b) 0 none (b) ON
1537 (c) 46210 CRC Error
counter (#623)
MAJOR
2
OFF
3841 (d) 46208 None
3844 (e) 46223 None
3845 (f) 46211 None
3846 (g) TEI None
Continued on next page
Blank This indicates that the Level 1 Status inquiry failed.
32773 This is a message from the ASAI-Line circuit pack indicating Level 1
has been deactivated.