Figure 8-2. BRI Port Local LAN Loop-Around Path
Table 8-61. Test #618 BRI Port Local LAN Looparound
Error
Code
Tes t
Result Description / Recommendation
1015 ABORT The port is not in the out-of-service state.
1. Display the Port Status form using the status bri-port UUCSSpp
command to determine which stations or adjuncts are on this port.
2. Use the extension shown on this form in the status station command to
determine whether the station or adjunct is active.
3. If the port is active, wait until it is idle, and use the busyout port UUCSSpp
command to place it in the out-of-service state and repeat this test.
!
WARNING:
Since the busyout command is destructive, using this command prior to
the port being idle causes every transaction associated with the ASAI on
the port to be torn down. Note that 3
rd
-party calls established by an ASAI
adjunct remain connected even though the port is taken out-of-service.
1139 ABORT The EPNs packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute the test port long UUCSSpp command
and review the results of the BRI Port Local LAN Looparound test to verify
the repair.
Continued on next page
BRI LINE
CIRCUIT
PACK
PACKET
INTERFACE
PACKET BUS
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
. . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
. . . .