Maintenance-Object Repair Procedures
555-233-143
8-160 Issue 1 May 2002
1141 ABORT The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Issue the test port long UUCSSpp command and review the results of the
BRI Port Local LAN Looparound test to verify the repair.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The loop-around test has failed.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other ports
on the board are idle. Reset the circuit pack by issuing the busyout board
UUCSS and the reset board UUCSS commands.
2. If the test fails again, execute test pkt P on the management terminal. If
this fails, follow the failure procedures the in PKT-BUS section.
3. If the tests executed in step 2 pass, the problem is local to the BRI board.
Replace the circuit pack.
PASS The BRI Port Local LAN Looparound test has passed.
Table 8-61. Test #618 BRI Port Local LAN Looparound Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page