ATM-BCH (ATM B-Channel Trunk)
Issue 1 May 2002
8-171555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call
state. Possible causes:
Received a DISConnect or RELease COMplete message with
cause value 52 (outgoing calls barred)
Received a DISConnect or RELease COMplete message with
cause value 54 (incoming calls barred)
Outgoing call renegotiated by the far end to another B channel in the
absence of SETUP message glare
Near end attempted a call on a B channel that the far end has
marked OOS
When running the short test sequence, pay close attention to the results of
the Call State Audit test (#257).
Table 8-69. ATM-BCH Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0Any Any Anytest port UUCSSppp
1(a) Any None test port UUCSSppp
18 0 busyout trunk grp/mbr release trunk
grp/mbr
129 (b) None WARNING OFF test port UUCSSppp
130 (c) test port UUCSSppp
257(d) Any Service State Audit test
(#256)
test port UUCSSppp
513(e) Any None WARNING OFF test port UUCSSppp
769(f) Any Service State Audit test
(#256)
test port UUCSSppp
1793(g) Any None test port UUCSSppp
3073(h) Any Service State Audit test
(#256)
test port UUCSSppp
3585(i) Any None none
3841(j) Any None WARNING OFF none
Continued on next page