ATM-BCH (ATM B-Channel Trunk)
Issue 1 May 2002
8-175555-233-143
Signaling Link State Audit Test (#255)
This nondestructive test checks the status of the TN230x ATM-CES Interface
circuit pack and the ATM D-channel (ATM-DCH) trunk, which are both important
elements to the health of the ATM-BCH trunk.
Table 8-71. Test #255 Signaling Link State Audit Test
Error
Code
Tes t
Result Description / Recommendation
None ABORT Internal system error
0 ABORT
1114 ABORT Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1018 ABORT Maintenance disabled
1. Enable maintenance. Enter y in the
Maintenance Tests? field on
page 2 of the change trunk-group form.
4 FAIL Signaling channel problem
1. Look for errors or alarms against the ‘‘ATM-SGRP (ATM Signaling Group)’’
and ‘‘ATM-DCH (ATM D-Channel Port)’’ MOs.
8 FAIL TN230x circuit pack failed
1. See the ‘‘ATM-INTF (TN2305/6)’’ MO.
PASS Signaling link OK.
Continued on next page