Maintenance-Object Repair Procedures
555-233-143
8-180 Issue 1 May 2002
1020 ABORT TN230x circuit-pack problem
1. See the ‘‘ATM-INTF (TN2305/6)’’ MO.
1024 ABORT Maintenance/Test digital port active
1. Wait until amber and green LEDs on the Maintenance/Test circuit pack are
OFF.
2. Rerun the test.
3. If the problem persists, see ‘‘M/T-DIG (Maintenance/Test Digital Port)’’
MO.
1113 ABORT Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check test).
1116 ABORT Switch could not change the service state
1. See if calls are active. Run status trunk grp#/mbr#.
2. If a call is active, proceed as for Error Code 1119.
If not, check the Error and Alarm Logs and see ‘‘ATM-TRK (Circuit
Emulation Service Circuit Pack)’’.
1117 ABORT ISDN service message outstanding
1. Wait 2 minutes. Then try again.
1118 ABORT Far-end not administered
1. Check the administration of the far end of the ATM trunk. Run status
trunk grp#/mbr#.
2. Try the test again.
1119 ABORT Test call aborted, normal call attempted
1. Wait for the call to finish normally, or drop it by running busyout trunk
grp#/mbr#.
2. When the trunk is idle, retry the test.
1120 ABORT Trunk OUT-OF-SERVICE/FAR-END
1. Try to change the service state via Test #256 (Service State Audit test).
2. Try the test again.
1122 ABORT No test-line number for the far-end switch
1. Check the Trunk Group Administration form.
1123 ABORT No Feature Access Code administration for this Facility test
1. Check the Dial Plan and Feature Administration forms.
Table 8-74. Test #258 ISDN Test Call Continued