ATM-BCH (ATM B-Channel Trunk)
Issue 1 May 2002
8-181555-233-143
2000,
2012,
None
ABORT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2035 ABORT Call timed out
1. Wait 1 minute, and try again.
2036–
2037
ABORT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2038–
2039
ABORT Problem reading test data
1. Wait 1 minute, and then try again.
2. If the test aborts again, there is a serious internal problem.
2040 ABORT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2041 ABORT Call timed out
1. Wait 1 minute, and try again.
2066 ABORT Could not establish test call
1. Retry the command up to 5 times at 1-minute intervals.
2067 ABORT Call timed out
1. Wait 1 minute, and try again.
2074 ABORT Bit and Block Error query failed
1. Retry the command up to 5 times at 1-minute intervals.
2. If the test continues to abort, there may be a serious internal problem in the
Maintenance/Test Digital port. See ‘‘M/T-DIG (Maintenance/Test Digital
Port)’’.
2075 ABORT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2201–
2205
ABORT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2206 ABORT Could not allocate needed resources
1. Retry the command at 1-minute intervals up to 5 times.
Table 8-74. Test #258 ISDN Test Call — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page