Maintenance-Object Repair Procedures
555-233-143
8-190 Issue 1 May 2002
Critical Reliability
1. Enter status pnc, and ensure that the A-PNC is active.
If not, request a PNC interchange using the reset pnc interchange
command.
2. Enter busyout pnc-standby.
3. Enter change system-parameters duplication, and change the Enable
Operation of PNC Duplication field to n.
4. Enter busyout atm pnc n (port network’s number).
5. Enter remove atm pnc n (port network’s number) to remove both ATM-EI
boards, or enter change atm pnc to remove the B-side ATM-EI board.
6. Enter change system-parameters duplication, and change the Enable
Operation of PNC Duplication field to y.
Changing Circuit Pack Location or ATM Address
Standard, Duplex or High Reliability
NOTE:
These systems are not equipped with PNC duplication.
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
Connections’’ above).
2. Add an ATM PNC connection (see ‘‘Adding ATM PNC Connections’’
above).
A-side ATM-EI—Critical Reliability
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
Connections’’ above).
2. Add an ATM PNC connection (see ‘‘Adding ATM PNC Connections’’
above).
B-side ATM-EI—Critical Reliability
1. Enter status pnc, and ensure that the A-PNC is active.
If not, request a pnc interchange using the reset pnc interchange
command.
2. Enter busyout pnc-standby.
3. Enter list config carrier, and verify that an ATM circuit pack is assigned for
the new location. If not, add the ATM circuit pack’s translations.
4. Enter busyout atm pnc n (connection number) b-pnc.
5. Enter change atm pnc n (connection number) and change circuit pack
location for the B side.
6. Enter release pnc-standby.