Maintenance-Object Repair Procedures
555-233-143
8-194 Issue 1 May 2002
g. Error Type 513 The ATM Crosstalk test failed. The board is either
writing to or reading from a TDM time slot that is not allocated to the board.
1. Test the board (test board UUCSS), and follow the test procedures
suggested for this test. In random tests of a single DSP during low
or high traffic, the same DSP can be tested more than once.
h. Error Types 769 and 770 are board-degraded alarm errors that result
when the ATM switch is sending corrupted cells or excessive AAL/LAP-D
retransmissions (off-board ATM cell corruption errors). These errors
indicate the detection of a problem in handling ATM cells that are received
from the fiber interface.
Aux Data:
The problem is most likely not on the ATM-EI circuit pack reporting the
errors, but it could be due to one or more of the following reasons:
The fiber is not snugly connected to either the board or the ATM
switch.
The EPNs packet bus is corrupting the cells. See ‘‘PKT-BUS
(Packet Bus)’’ (Aux Data 35 only).
The fiber between the ATM switch and the ATM-EI is too long
(greater than 2 km for multimode fiber). Use loopback to see if the
fiber is corrupting the cells.
Some other ATM-EI board is not receiving the cells properly.
The intervening ATM switch is dropping the ATM cells due to a
shortage of bandwidth, or the S8700 Multi-Connect system is using
more than the subscribed bandwidth.
Error Type 771 The ATM switch is sending cells with unknown VPI and
VCI address (wrong connection).
1. Ensure that the ATM-EI board address on the ATM switch matches
the ATM-EI (ATM) address on the S8700 Multi-Connect side.
i. Error Types 1024-1151 These errors represent problems detected by
the ATM-EI board in response to SETUP and ADDPARTY requests from
software.
The Error Types and descriptions are in Table 8-81 on page 8-195.
Aux Data values represent port network and angel numbers and are
in Table 8-82 on page 8-196.
Error
Type
Aux
Data Description
769 34 Excessive AAL-5 retransmission requests
769 35 Excessive LAP-D retransmission requests
770 25 Uncorrectable ATM cell headers threshold
771 26 VPI, VCI pair unknown